Sale Additel 227 Multifunction Process Calibrator NEW
ADDITEL
Additel’s new Multi-functional Documenting Process Calibrator series takes portability, functionality, and accuracy to a whole new level and packages it with an intuitive and easy to use color touchscreen display. This series includes an advanced documenting pressure calibrator (ADT227) and an advanced documentation process calibrator with a builtin HART communicator (ADT227-HART). Additionally, each calibrator has an ATEX certified intrinsically safe option (ADT227Ex) allowing you to perform calibration in the harshest of environments.
$3,125.00
Additel 227 Multifunction Process Calibrator NEW
Additel’s new Multi-functional Documenting Process Calibrator series takes portability, functionality, and accuracy to a whole new level and packages it with an intuitive and easy to use color touchscreen display. This series includes an advanced documenting pressure calibrator (ADT227) and an advanced documentation process calibrator with a builtin HART communicator (ADT227-HART). Additionally, each calibrator has an ATEX certified intrinsically safe option (ADT227Ex) allowing you to perform calibration in the harshest of environments.
Sourcing, simulating and measuring pressure, temperature and electrical signals
Built-in Full Hart Communicator (ADT227-HART)
Built-in Barometer
Intrinsically safe models available (Ex)
Large Smartphone Like Touchscreen User Experience
USB Type-C and Bluetooth communications
IP67 Rated
High Voltage Measurement Capability (±300V AC)
True RMS Voltage Meter Capability
Dual channel pressure module ports
High Static Differential Pressure Measurement 0.002% FS
ISO 17025-accredited calibration w/data included
Easy-to-use Cellphone Like Interface
The ADT227 series brings an all new user interface to the world of process calibrators. With a menu driven interface and a small size/weight, the ADT227 is the industry's smallest advanced multifunctional process calibrator with an intrinsically safe version to boot (ADT227Ex). It adopts advanced human hand engineering design for the most convenient field handheld process calibrator available. The ADT227 has been developed with a powerful embedded operating system which solves common problems of other designs including slow response, cumbersome key operation, high power consumption and overall slow processing.
Accuracy
Additel's new and improved ADT227 series provides much improved accuracies including an electrical accuracy of 0.005% RD + 0.005% FS, high-static differential pressure mode accuracy to 0.002% FS and across the board improvements in temperature measurement accuracies.
Thermocouple Measurement Performance
The ADT227 series delivers highly improved thermocouple measurement capabilities by vastly improving the cold junction compensation(CJC) specifications and a much improved stabilization time.
Portable and Robust
The demands of remote calibration work can be challenging. The ADT227series is lightweight and highly portable and utilizes an advanced color LCD screen to help ensure you can easily see, even in the (Ex) intrinsically safe versions. All models in the ADT227 family have been designed with ruggedness and dependability in mind and meet IP67 standards with a 1-meter drop test, 4G vibration, xenon exposure and 130g steel ball drop testing of the display. Other environmental conditions have also been considered, such as temperature and humidity. To combat these external elements, Additel has designed a unique internal circuit design and process technology to allow for the utmost confidence in your critical calibration and measurement work.
Intrinsically Safe Option
The Additel 227Ex series calibrators have passed the most stringent testing by certified organizations to acquire intrinsically safe certificates, ATEX, IECEX. The explosion-proof grade (Ex ia IIC T4 Ga), can be widely used in potentially explosive environments, such as oil and gas platforms, oil refineries, chemical and petrochemical plants, pharmaceutical industries, energy and gas processing industries. Each intrinsically safe calibrator has an advance transflective color LCD display which has enhanced visibility when viewed in direct sunlight. No matter where your work takes you, these calibrators are up to the task.
Voltage Meter (RMS)
The Additel 227 non-Ex version is equipped with “true effective value” RMS measuring function, which can measure the RMS of various waveforms with no need to consider distortion or waveform parameters and other errors caused by various waveforms.
Automated Tasks for Paperless Calibration Management
Additel 227 Series Calibrators come with a powerful documenting calibration task application which provides a turnkey solution for automation and paperless calibration management. Tasks are easily created for temperature, pressure, flow and loop instruments. Up to 10,000 documented tasks for ADT227 and up to 1,000 documented tasks for ADT227Ex can be stored in the extensive on-board memory. Many tasks, when executed, are fully automated in data collection and performance validation, such as pass/fail and hysteresis calculations. All information can be integrated into Additel’s ACal software for additional calibration management.
Full HART Communicaton ( For ADT227-HART only)
The built-in full HART communicator will work with most HART transmitters . The ADT227-HART contains an extensive DD library to meet the needs of your smart transmitter. Our DD library is updated on a regular basis and at no additional cost. The ADT227Ex-HART is integrated with the HART communication functions, permitting users to monitor, control, and calibrate HART instrumentations. It's an ideal device for calibrating, maintaining, and troubleshooting HART instrumentations.
Targeted Application Features
The onboard applications provide a useful selection of features including HART communicator, high static differential pressure mode, pressure leak test, safety valve test, analog transmitter calibration, unit converter, thermal calculator, and snapshots to name a few. High static differential pressure mode uses two sensors, unique calculation technology to achieve a differential pressure measurement to 0.002% FS at high static pressures. The leak test will automatically calculate the pressure drop to determine a leak condition. The safety valve test is a specialized task which captures the exact pressure release point by taking 10 readings per second during a valve crack test. You will find this and much more as we continue to develop new apps at Additel.
Data Logger ( For ADT227 & ADT227-HART only)
The calibrator can record pressure, temperature and electrical signals readings for a long period. Recorded values can be displayed numerically or graphically to identify trending. ADT227 & ADT227-HART can store up to 500 results. Each result can record up to 1,000,000 recording and each recording can record a maximum of 7 channels' values. These results can be easily exported to Additel application software. Each log session is easily configured at a set interval and each reading is provided with a date and time stamp.
Connectivity and Battery
Users can remotely connect mobile devices to the ADT227 via Bluetooth with an unobstructed distance up 20 meters. The included USB type-C comm port and cable provide a hard wired communication option as well as charging for the removeable Li-ion battery, which provides up to 35 hours of run time.
Time Saving Features
In addition to all the great features mentioned above, the ADT227series is loaded with time saving features like our builtin pressure and temperature converter, thermal calculator, wiring diagram guide for assisting with electrical connections, a built-in diagnostic center including intelligent alarm messaging and a real time error report and comprehensive selftesting to help our customers get the very most out of their investment in Additel calibration tools.
Specifications :
Operating Temperature
-10°C to 50°C
Specification guaranteed temperature range
10°C to 30°C
Storage Temperature
-20°C to 70°C
Humidity
<95%, non-condensing
Power supply
6600mAh, 23.8Wh lithium battery, charging time 4~6 hours, battery pack can be charged independently
User interface
Icon drive menus
Ports protection voltage
50V max
Display
5.0 inch 480 x 800 mm TFT LCD capacitive screen
Data logger
500 results, 7 channels x 100,0000 readings
Maximum altitude
3000 meters
European Compliance
CE Mark
Electrical Connection
Ø4mm sockets and flat mini-jack thermocouple socket
Size
6.97" x 4.13" x 2.04" (177 mm x 105 mm x 52 mm)
Weight
1.6 lb (0.7 kg)
Battery
Rechargeable Li-ion battery (included)
Battery Life
Typically 16 hours
Battery Charge
110V/220V external power adapter included. Battery can be charged external to the unit. Typically charge time is 6-8 hours.
External pressure module
Dual channel aerial plug, can connect two digital pressure modules
Warm-up time
Full specification performance is achieved after a 10 minute warm-up time
ROHS compliant
Rohs II Directive 2011/65/EU, EN50581:2012
Display rate
3 readings per second
Barometric Accuracy (Built-in barometer)
50Pa
IP protection
level IP67, 1 meter drop test
Communication
Isolate USB-TYPEC (slave), Bluetooth BLE
Calibration
ISO 17025 accredited calibration with data
Warranty
3 years
INCLUDED :
110V/220V external power adapter
Chargeable Li-ion battery
Test leads
Right angle test leads kit
Pressure module connection cable
Hanging strap with magnet
Manual
calibration certificate
Optional Accessories :
Digital Pressure Modules
Intrinsically Safe Digital Pressure Modules
Differential Pressure Manifold, -15 to 3,000 psi
Pressure module connection cable
USB Cable type A to type C
USB Cable type A to type C for Ex handheld models
Cable kit
Hard carrying case
Soft carrying case
Additel/Acal Task management software
Additel/Acal Automated calibration software
Also you can check product : Sale Additel 87X-1210 Thermocouple Calibration Furnaces NEW