Loading...

Sale Emerson AMS 2140 Machinery Health Analyzer USED

Emerson

The AMS 2140 Machinery Health Analyzer takes vibration data and analysis measurements to the next level. It features simultaneous four-channel plus phase data collection and unique peak detection capabilities for the earliest indication of bearing and gearbox degradation. In addition to delivering faster data collection for less time in the field or more machines monitored, the AMS 2140 is ergonomically designed for comfortable, single hand operation all day long.


3,028.54€


Qty:

Total Price:

  • Free Shipping

Emerson AMS 2140 Machinery Health Analyzer USED

Features

Includes new PeakVue Plus technology for earliest and simplest indication of bearing degradation and severity.

One of the fastest vibration analyzers on the market

Ergonomically designed to make long days in the field easier

Data collection, vibration analysis, balancing and motor diagnostics in a single unit

Monitor a broad range of machinery from variable speed equipment, complex gearboxes, high speed compressors and sleeve bearing turbo machinery

Pre-configured analysis experts to easily test and diagnose your toughest issues

The Four-Channel Advantage
While the AMS 2140 is available in single and dual channel options, it is the four-channel option that delivers the most advantages to a predictive maintenance program. The AMS 2140 is one of the fastest collectors in the industry when collecting a measurement point. With four-channel capabilities, speed through the data collection route is increased even more. And unlike other four-channel units on the market, the AMS 2140 delivers all four channels when you need them the most – critical equipment startup and troubleshooting diagnostics.

Monitor More Machines in Less Time Using True
Four-Channel. Using a triaxial accelerometer, the AMS 2140 simultaneously collects vertical, horizontal, and axial readings on a bearing. Place the sensor on the measurement point, press the button, and when collection is complete move on to the next bearing. Data collection time is reduced by as much as 50% compared to other vibration collectors. Faster data collection translates into less time in harsh or hazardous environments, more machines monitored, and more time dedicated to higher value tasks like analysis and diagnostics.

Four-Channel Data Collection Enables Powerful
Diagnostic Options. Perform additional advanced diagnostics and deeper dive diagnostic tests using fourchannel collection. With four-channel monitoring, you will gain additional data and diagnostic tools to help you identify the root cause of your toughest equipment problems. For example,

View dual orbit plots, one on either side of the coupling or dual orbit plots of both sleeve bearings on a turbine, fan, or other production asset to see how the shaft is moving in relation to the bearing races.

Collect ODS Modal data 66% faster to animate physical movement of machinery, an important tool in identifying the root cause of chronic or complex machinery problems. Having the information you need for advanced diagnostics faster allows you to move more quickly towards identifying machinery faults or determining if it is safe to continue startup of turbo machinery.

More Power That is Easy to Carry into the Field
Route data collection can be a long process – and you need an analyzer that has the battery power to last an entire shift and comfortable enough to carry around all day. The AMS 2140 takes advantage of ergonomic principles and advanced engineering to address these needs. This thinner, lighter analyzer is comfortable to carry on long routes and operate with one hand. The shoulder strap has a large, slip-proof padded area to reduce friction on the neck and back. Connecting the strap is as simple as the push of a button, making it easy to quickly reconfigure for left-or right-hand users.

Visibility in Any Environment.
Struggling to see the details of spectrum or waveform data due to sunlight o other lighting conditions is a thing of the past. The AMS 2140’s glove-friendly touch screen features an auto light sensor that adjusts the screen’s backlight to the ambient lighting of the environment for optimal viewing. Visibility is maintained as you move from one area of the plant to another – from direct sunlight to darker interior locations. A backlit keypad allows continued operation of the unit in the darkest environments. In the office, the built-in stand sets the unit at the best angle for viewing data. Charger and communication cables are located at the top of the unit so they do not interfere with the standing position.

Uninterrupted Route Collection.
The AMS 2140 has the longest battery life available in the market, which means no more long trips back to the office to dump data or deal with a dead battery. New Lithium-Ion batteries extend battery life and route coverage to a full shift – maybe two – from a single charge. If you do choose to change out the battery, the unit is re-engineered to make the task simple enough to accomplish even in the field. In addition, an external charger allows you to charge a spare battery while you continue to use your analyzer in the field. A car charger option enables you to deliver a charge en route. The AMS 2140 uses local hotspot availability to wirelessly transfer data back to the office for quick analysis or from remote locations to a centralized server. Your team can perform route collection and analysis in parallel to maximize your efficiency.

Embedded Intelligence
The ability to perform additional diagnostic tests at the machine site transforms simple data collection into an ffective machinery health program. In today’s demanding work environment, it is difficult to find the time to acquire advanced analysis skills. Embedded intelligence, enabled through Analysis Experts, allow even a novice user to conduct sophisticated troubleshooting tests with the touch of a button. Technicians don’t need to remember the complexity of setting up a test they only perform a few times a year – yet they can gain the benefit of its diagnostics when needed. The bottom line impact is that users can quickly do more in the field with the AMS 2140, avoiding further deterioration of equipment condition.

Specifications :

Hardware Specifications

Physical Dimensions

Dimensions
248 mm (8.8”) high, 40 mm (1.57”) deep, 226 mm (8.9”) wide

Weight
1.79 kg (3.95 lbs)

LCD Display
151 x 115 mm (6” x 4.5”) color TFT w/ LED backlight
Resolution 640 x 480 pixels. Touchscreen - XY resistive

Keypad
Tactile Dome buttons, 12 tactile dome buttons with backlit keys, Electroluminescent panel illumination

Built-in Stand

Environmental
Operating Temperature
-10° to 50°C (-4° to 122°F)

Long-term Storage Temperature
-20° to 35°C (-4° to 95°F) with battery1

Long-term Storage Temperature
-40° to 65°C (-40° to 150°F) without battery

Environmental Rating
Sealed enclosure, IP-65 rated

Battery and Charging

Battery
Type Rechargeable Lithium-Ion battery pack
7.2 Volts (Nominal) Protected Output
On pack LED readout
10 hours of continuous use
4 hours recharge time (Nominal)
Charging temperature 10° to 35°C (50° to 95°F)

Frequency Analysis

A/D Converter
24 bits of precision

Averaging Modes
Normal, exponential, peak hold, order tracking, negative averaging,synchronous time

Cursors Spectrum
Single, Harmonic, Moving Harmonic, Sideband, and Time/Frequency for waveform

Dynamic Range
Converter has 120 dB dynamic range

Frequency Range
DC to 10 Hz minimum, DC to 80 kHz maximum

Frequency Units
Hz, CPM, Orders

Full-scale Range
Accelerometer input: 0-20 V, Volts input -20 V 20 V

Noise Floor
Typically less than 20 μV for a 400-line spectrum at 1,000 Hz maximum frequency

Number of Averages
5,000 in Route mode, 10,000 in Job mode

Resolution
100, 200, 400, 800, 1600, 3200, 6400, or 12800 lines of resolution.
True Zoom provides effective resolution of up to 300,000 lines

Response
Flat to DC for non-integrated and DC-coupled signals; optional AC coupling -3 dB at 1 Hz

Scaling
Linear or Log, both X and Y

Windows
Hanning or uniform

Data Storage Capacity

Internal Memory
1 GB

External Memory
SD (Secure Digital). Virtually unlimited memory with off the shelf SDHC SD cards
up to 32 GB

Data Analysis Speed

400 line, 1000 HZ spectrum
67% overlap 6 avg/sec

1600 line, 1000 Hz spectrum
67% overlap 3 avg/sec

Input Specifications

Input Signals
A 2-milliampere, 20-volt (nominal), constant-current power supply inside the
analyzer powers sensors such as accelerometers connected to the accelerometer
channel inputs.

Full Scale Input Level
Accel Channels A, B, C, D; Volts A, B, C, D

Accelerometer Input
0-20 V
Full scale vibration level is /- 90 g’s when using a 100- mv/g accelerometer

Volts Input
-20 V to 20 V

Input Impedance
Greater than 125K ohms

Input Signal Types

Dynamic Signals
Single channel/Dual channel/Four channel

DC Signals
Single channel/Dual channel/Four channel

RPM/tach Signal
TTL pulse

Keypad Entry
Full alphanumeric capability

Four-Channel Data Collection
Simultaneous four-channels Dynamic Input Phase
Simultaneous four-channels DC Input
Simultaneous four-channel Route collection Phase
Simultaneous four-channel Display - Spectrum and Waveform
Simultaneous four-channel Transient Phase
Simultaneous four-channel ODS/Modal Phase
Simultaneous four-channel Volt/Displacement Phase
(for sleeve bearing monitoring)
Simultaneous Dual Orbits Display [accelerometer/displacement]
(for rolling element/sleeve bearing monitoring)
Simultaneous four-channel Cross Channel Phase

In-field Route Analysis Tools

Fault Frequency Overlays on Plot
Identifies source of vibration peaks

Parameter Trends
Up to 12 parameters trended over 2 years

Colored Alarms 
Shows specific parameter in alarm and percentage of alarm value

Waveform Autocorrelation
Identifies whether impacting is periodic or random

Input Sensor Types

Portable Sensors
Accelerometers, velocity probes, RPM/tachometer probes, temperature sensors,
flux coil, current clamp, pressure sensors, triaxial accelerometer, impact hammer

Installed Sensors
Any vibration or dynamic sensor with a voltage output; any DC-type signal

Input Unit Types
Vibration Signals Units Acceleration g’s
Velocity In/sec or mm/sec
Displacement Mils or microns
Other Dynamic Signals Any user-specified unit
DC Signals Any user-specified unit
Tachometer Input
RPM Range 1 to 100,000 RPM
Tach Input Level TTL input, built in conditioning for non-TTL signals, adjustable trigger level.
The tachometer input measures a once-per-rev pulse to measure RPM.
Advanced Acquisitions
PeakVue Selectable filters
Pseudo Tach Generates tach pulses for hidden shafts
Demodulation Selectable filters

Wireless

Bluetooth
2.0 Class 2 (optional) Range up to 10 m

Wireless
802.11 b/g Range up to 33 m

Connecting to a PC

Requirements

Connections/Outpu
 USB 2.0, 100 m Ethernet.

Compatible Software
AMS: Machinery Manager v5.6 or greater.

Accuracy – all measurements taken at a temperature of 25°C

For All Dynamic Input Channels

Frequency Accuracy (crystal based
0.02%

Non-Integrated Spectral Amplitude Accuracy
5% over the range of 3 Hz to 65 kHz, 0.001 - 10 Vrms input, with SST on for measurements 3-20 Hz

Single Integrated Spectral Amplitude Accuracy
5% over the range of 10 Hz-20 kHz, 3% over the range of 20 Hz- 20 kHz 

DC Accuracy
3% (5 mv) over the input range of 0.1 V to 20 V

Overall Level (W/Averaging, band limited)
5% over the range of 5 Hz - 65 kHz, 0.001 to 10 Vrms

Peak and Phase Measurements

1X Synchronous Peak Accuracy
3% over the range of 3 Hz – 1,500 Hz, 0.01 - 10.0 Vrms

1X Synchronous Phase Accuracy
5 deg over the range of 3 - 1,500 Hz [180- 90,000 RPM]

Tachometer Frequency Accuracy
0.01% ( /-0.1 rpm) over the range of 1-1,600 Hz

AMS 2140 Hazardous Area Certifications1

North America
Certified in the US and Canada to safety standards for
Class I, Division 2 Groups A, B, C, D
Class II, Division 2 Groups F, G

Europe
Certified to the ATEX standards EN 60079-0:2012 & EN 60079-11:2012
II 3 G Ex ic [ic] IIC T4 Gc -20°C ≤ Ta ≤ 50°C

International
Certified to the IECEx standards IEC 60079-0 Edition 6.0 (2014) & IEC 60079-11
Edition 6.0 (2011) Ex ic [ic] IIC T4 Gc -20°C ≤ Ta ≤ 50°C

INCLUDED :
Reinforced case
Shoulder strap
Magnetic base
Accelerometer cable
Accelerometer
Counter lamp
Battery charger

Also you can check product : Sale Emerson CSI 2140 Machinery Health Analyzer USED

  • Availability: 14 In Stock
  • Model: AMS 2140
  • SKU: 062IDUAMS2140
  • Brand: Emerson

Reviews

There are no reviews for this product.

Write a Review

*
*
Note: Do not use HTML in the text.
*
captcha
*