Sale Emerson CSI 2140 Machinery Health Analyzer USED
Emerson
The Emerson CSI 2140 Machinery Health Analyzer is a 24-bit precision vibration analysis device which allows for accurate measurement of frequency vibrations from 10 Hz to 80 kHz. Technicians can choose from averaging modes like exponential, peak hold, order tracking and more. Emerson CSI 2140 test instruments synthesize data from multiple technologies, including oil analysis, thermography, balancing and vibration into an AMS Suite database, and then combine them with alerts relating to other plant assets for a holistic view of plant health. One, two and four-channel options are available. Four-channel devices collect vertical, horizontal and axial readings via a triaxial accelerometer.
$2,245.00
Emerson CSI 2140 Machinery Health Analyzer USED
The Emerson CSI 2140 Machinery Health Analyzer is a 24-bit precision vibration analysis device which allows for accurate measurement of frequency vibrations from 10 Hz to 80 kHz. Technicians can choose from averaging modes like exponential, peak hold, order tracking and more. Emerson CSI 2140 test instruments synthesize data from multiple technologies, including oil analysis, thermography, balancing and vibration into an AMS Suite database, and then combine them with alerts relating to other plant assets for a holistic view of plant health. One, two and four-channel options are available. Four-channel devices collect vertical, horizontal and axial readings via a triaxial accelerometer.
24-bit precision
10 Hz - 80 kHz frequency range
Portable, lightweight, thinner model
Simple data collection with powerful analysis tools
Four-channel data collection provides faster route completion and offers advanced diagnostics
Intelligence guides embedded, supplying data analysis and test set-up
Ergonomic design improves accessibility
Data is wirelessly uploaded to AMS Suite from field
Specifications :
Hardware Specifications
Physical Dimensions
Dimensions
248 mm (8.8”) high, 40 mm (1.57”) deep, 226 mm (8.9”) wide
Weight
1.79 kg (3.95 lbs)
LCD Display
151 x 115 mm (6” x 4.5”) color TFT w/ LED backlight
Resolution 640 x 480 pixels. Touchscreen - XY resistive
Keypad
Tactile Dome buttons, 12 tactile dome buttons with backlit keys, Electroluminescent panel illumination
Built-in Stand
Environmental
Operating Temperature
-10° to 50°C (-4° to 122°F)
Long-term Storage Temperature
-20° to 35°C (-4° to 95°F) with battery1
Long-term Storage Temperature
-40° to 65°C (-40° to 150°F) without battery
Environmental Rating
Sealed enclosure, IP-65 rated
Battery and Charging
Battery
Type Rechargeable Lithium-Ion battery pack
7.2 Volts (Nominal) Protected Output
On pack LED readout
10 hours of continuous use
4 hours recharge time (Nominal)
Charging temperature 10° to 35°C (50° to 95°F)
Frequency Analysis
A/D Converter
24 bits of precision
Averaging Modes
Normal, exponential, peak hold, order tracking, negative averaging,synchronous time
Cursors Spectrum
Single, Harmonic, Moving Harmonic, Sideband, and Time/Frequency for waveform
Dynamic Range
Converter has 120 dB dynamic range
Frequency Range
DC to 10 Hz minimum, DC to 80 kHz maximum
Frequency Units
Hz, CPM, Orders
Full-scale Range
Accelerometer input: 0-20 V, Volts input -20 V 20 V
Noise Floor
Typically less than 20 μV for a 400-line spectrum at 1,000 Hz maximum frequency
Number of Averages
5,000 in Route mode, 10,000 in Job mode
Resolution
100, 200, 400, 800, 1600, 3200, 6400, or 12800 lines of resolution.
True Zoom provides effective resolution of up to 300,000 lines
Response
Flat to DC for non-integrated and DC-coupled signals; optional AC coupling -3 dB at 1 Hz
Scaling
Linear or Log, both X and Y
Windows
Hanning or uniform
Data Storage Capacity
Internal Memory
1 GB
External Memory
SD (Secure Digital). Virtually unlimited memory with off the shelf SDHC SD cards
up to 32 GB
Data Analysis Speed
400 line, 1000 HZ spectrum
67% overlap 6 avg/sec
1600 line, 1000 Hz spectrum
67% overlap 3 avg/sec
Input Specifications
Input Signals
A 2-milliampere, 20-volt (nominal), constant-current power supply inside the
analyzer powers sensors such as accelerometers connected to the accelerometer
channel inputs.
Full Scale Input Level
Accel Channels A, B, C, D; Volts A, B, C, D
Accelerometer Input
0-20 V
Full scale vibration level is /- 90 g’s when using a 100- mv/g accelerometer
Volts Input
-20 V to 20 V
Input Impedance
Greater than 125K ohms
Input Signal Types
Dynamic Signals
Single channel/Dual channel/Four channel
DC Signals
Single channel/Dual channel/Four channel
RPM/tach Signal
TTL pulse
Keypad Entry
Full alphanumeric capability
Four-Channel Data Collection
Simultaneous four-channels Dynamic Input Phase
Simultaneous four-channels DC Input
Simultaneous four-channel Route collection Phase
Simultaneous four-channel Display - Spectrum and Waveform
Simultaneous four-channel Transient Phase
Simultaneous four-channel ODS/Modal Phase
Simultaneous four-channel Volt/Displacement Phase
(for sleeve bearing monitoring)
Simultaneous Dual Orbits Display [accelerometer/displacement]
(for rolling element/sleeve bearing monitoring)
Simultaneous four-channel Cross Channel Phase
In-field Route Analysis Tools
Fault Frequency Overlays on Plot
Identifies source of vibration peaks
Parameter Trends
Up to 12 parameters trended over 2 years
Colored Alarms
Shows specific parameter in alarm and percentage of alarm value
Waveform Autocorrelation
Identifies whether impacting is periodic or random
Input Sensor Types
Portable Sensors
Accelerometers, velocity probes, RPM/tachometer probes, temperature sensors,
flux coil, current clamp, pressure sensors, triaxial accelerometer, impact hammer
Installed Sensors
Any vibration or dynamic sensor with a voltage output; any DC-type signal
Input Unit Types
Vibration Signals Units Acceleration g’s
Velocity In/sec or mm/sec
Displacement Mils or microns
Other Dynamic Signals Any user-specified unit
DC Signals Any user-specified unit
Tachometer Input
RPM Range 1 to 100,000 RPM
Tach Input Level TTL input, built in conditioning for non-TTL signals, adjustable trigger level.
The tachometer input measures a once-per-rev pulse to measure RPM.
Advanced Acquisitions
PeakVue Selectable filters
Pseudo Tach Generates tach pulses for hidden shafts
Demodulation Selectable filters
Wireless
Bluetooth
2.0 Class 2 (optional) Range up to 10 m
Wireless
802.11 b/g Range up to 33 m
Connecting to a PC
Requirements
Connections/Outpu
USB 2.0, 100 m Ethernet.
Compatible Software
AMS: Machinery Manager v5.6 or greater.
Accuracy – all measurements taken at a temperature of 25°C
For All Dynamic Input Channels
Frequency Accuracy (crystal based
0.02%
Non-Integrated Spectral Amplitude Accuracy
5% over the range of 3 Hz to 65 kHz, 0.001 - 10 Vrms input, with SST on for measurements 3-20 Hz
Single Integrated Spectral Amplitude Accuracy
5% over the range of 10 Hz-20 kHz, 3% over the range of 20 Hz- 20 kHz
DC Accuracy
3% (5 mv) over the input range of 0.1 V to 20 V
Overall Level (W/Averaging, band limited)
5% over the range of 5 Hz - 65 kHz, 0.001 to 10 Vrms
Peak and Phase Measurements
1X Synchronous Peak Accuracy
3% over the range of 3 Hz – 1,500 Hz, 0.01 - 10.0 Vrms
1X Synchronous Phase Accuracy
5 deg over the range of 3 - 1,500 Hz [180- 90,000 RPM]
Tachometer Frequency Accuracy
0.01% ( /-0.1 rpm) over the range of 1-1,600 Hz
AMS 2140 Hazardous Area Certifications1
North America
Certified in the US and Canada to safety standards for
Class I, Division 2 Groups A, B, C, D
Class II, Division 2 Groups F, G
Europe
Certified to the ATEX standards EN 60079-0:2012 & EN 60079-11:2012
II 3 G Ex ic [ic] IIC T4 Gc -20°C ≤ Ta ≤ 50°C
International
Certified to the IECEx standards IEC 60079-0 Edition 6.0 (2014) & IEC 60079-11
Edition 6.0 (2011) Ex ic [ic] IIC T4 Gc -20°C ≤ Ta ≤ 50°C
INCLUDED :
Emerson AMS 2140 Unit
Original Box/Packaging
Lithium Ion Battery
Charger and AC Cable
x2 Wireless Vibration Monitors
x1 Vibration Probe & Cable
Also you can check product : Sale Emerson AMS 2140 Machinery Health Analyzer NEW